Langue de l’avis : Anglais · Aucun résumé vérifié en Français n’est disponible. Le texte enregistré est affiché; consultez les documents d’origine.

Tous les appels d’offres
21443-27-5482359

PCB Transformer Replacements at Beaver Creek Institution -Minimum

Correctional Service of Canada (CSC) · Ottawa , Ontario, Canada

Cet appel d’offres a fermé le 5 novembre 2026 à 09 h 00. Consulter les avis ouverts
Consulter la sourceTélécharger le PDF

Temps restant pour soumissionner

Fermé

FerméTransport et logistiqueFédéral

Renseignements généraux

Numéro de référence
21443-27-5482359
Palier de gouvernement
Federal
Type d’appel d’offres
Transportation & Logistics
Titre
PCB Transformer Replacements at Beaver Creek Institution -Minimum
Identifiant de la source
21443-27-5482359

Détails

Lieu
Ottawa , Ontario, Canada

Résumé

The Correctional Service Canada (CSC) requires the removal and replacement of two transformers at Beaver Creek Institution (Minimum) prior to December 31, 2026 to comply with federal regulations established under the Canadian Environmental Protection Act and the polychlorinated biphenyls (PCBs) Regulations. One existing pad-mounted transformer, installed in 1975, contains polychlorinated biphenyls (PCBs) at a concentration of 172 ppm, which exceeds the regulatory threshold. A second pole-mounted transformer has reached the end of its service life and, due to its age, may contain PCBs. Both transformers must be removed and replaced prior to the regulatory deadline of December 31, 2026. The work includes the supply and installation of replacement transformers, disposal of PCB-contaminated equipment and associated oil in accordance with applicable regulations, coordination of electrical outages and commissioning activities, and restoration of affected areas.

Description

The Correctional Service Canada (CSC) requires the removal and replacement of two transformers at Beaver Creek Institution (Minimum) prior to December 31, 2026 to comply with federal regulations established under the Canadian Environmental Protection Act and the polychlorinated biphenyls (PCBs) Regulations. One existing pad-mounted transformer, installed in 1975, contains polychlorinated biphenyls (PCBs) at a concentration of 172 ppm, which exceeds the regulatory threshold. A second pole-mounted...

Dates

Publication
19 octobre 2026 à 20 h 00
Date de clôture
5 novembre 2026 à 09 h 00

Documents

Classification

Catégories UNSPSC

25173900 *26130000 *26131800 *31282000 *39122100 *39122300 *72102201 *72151502

Catégorie normalisée

Transportation & Logistics

Source: CanadaBuys

Dernière modification : 2026-11-25 04 h 17 min 13 s