5P468-25-0291/A

Stage 2 - Rogers Pass Generator and Fuel Storage Replacement, Rogers Pass National Historic Site

Parks Canada Agency (PC) · Calgary, Alberta, Canada

Cet appel d’offres a fermé le 12 mai 2026 à 12 h 00. Consulter les avis ouverts
Consulter la source

Temps restant pour soumissionner

Fermé

FerméConstruction et infrastructureFédéral

Renseignements généraux

Numéro de référence
5P468-25-0291/A
Palier de gouvernement
Federal
Type d’appel d’offres
Construction & Infrastructure
Titre
Stage 2 - Rogers Pass Generator and Fuel Storage Replacement, Rogers Pass National Historic Site
Identifiant de la source
5P468-25-0291/A

Détails

Lieu
Calgary, Alberta, Canada

Résumé

5P468-25-0291/A Stage 2 - Rogers Pass Generator and Fuel Storage Replacement, Rogers Pass National Historic Site REQUIREMENT Parks Canada requires removal and replacement of a diesel generator and fuel tank in Rogers Pass operational compound at Rogers Pass National Historic Site. The Rogers Pass operational compound is currently supported by two diesel generators that provide emergency power during utility grid outages. In coordination with Mount Revelstoke and Glacier National Parks, the project requires the removal and replacement of one existing 300 kW diesel generator to ensure continued reliability of standby power systems. This scope includes the complete decommissioning of the existing generator, followed by the procurement and installation of a new generator unit of equivalent or greater capacity. All associated mechanical and electrical integration work—such as fuel system connections, controls interfaces, structural mounting, commissioning, and final testing—is part of the project scope. In addition to generator replacement activities, the project requires the installation of a new 3,000 gallon fuel storage tank to support extended-power operation. A snow shelter structure must also be constructed to protect the tank from heavy winter snow loads typical of the Rogers Pass environment. TWO STAGE SELECTION PROCESS This posting is the Stage Two of a two-stage solicitation process: the first stage was to evaluate the qualifications of all interested suppliers. The second stage (Stage Two) is to invite the qualified suppliers to provide further qualifications and a financial bid on the project based on the specifications and drawings. Only qualified suppliers have been invited to bid. Potential and interested sub-contractors are invited to add their company’s name under the section “Partner with another business”

Description

5P468-25-0291/A Stage 2 - Rogers Pass Generator and Fuel Storage Replacement, Rogers Pass National Historic Site REQUIREMENT Parks Canada requires removal and replacement of a diesel generator and fuel tank in Rogers Pass operational compound at Rogers Pass National Historic Site. The Rogers Pass operational compound is currently supported by two diesel generators that provide emergency power during utility grid outages. In coordination with Mount Revelstoke and Glacier National Parks, the pro...

Dates

Publication
22 avril 2026 à 20 h 00
Date de clôture
12 mai 2026 à 12 h 00

Documents

Comment soumissionner

Classification

Catégories UNSPSC

72151500 *72151800

Catégorie normalisée

Construction & Infrastructure

Source: CanadaBuys

Dernière modification : 2026-09-09 20 h 57 min 58 s