Langue de l’avis : Anglais · Aucun résumé vérifié en Français n’est disponible. Le texte enregistré est affiché; consultez les documents d’origine.

Tous les appels d’offres
26-58103

Bio-capacitance probe system

National Research Council of Canada (NRC) · Ottawa, Ontario, Canada

Cet appel d’offres a fermé le 24 août 2026 à 10 h 00. Consulter les avis ouverts
Consulter la sourceTélécharger le PDF

Temps restant pour soumissionner

Fermé

FerméOffice Supplies & EquipmentFédéral

Renseignements généraux

Numéro de référence
26-58103
Palier de gouvernement
Federal
Type d’appel d’offres
Office Supplies & Equipment
Titre
Bio-capacitance probe system
Identifiant de la source
26-58103

Détails

Lieu
Ottawa, Ontario, Canada

Résumé

Acquisition of a new four-probe system enabling real-time measurement of bio-capacitance for cell culture in bioreactors, for up to four bioreactors in parallel. This system will enable real-time estimation of viable cell concentration in those bioreactors. Measuring bio-capacitance at multiple frequencies, at regular intervals, in order to obtain the capacitance distribution spectrum of the cells, thereby enabling the real-time calculation of other critical cell culture parameters such as cell size, internal cell conductivity, and critical frequency. The probes to be acquired under this procurement must be compatible with the different types of bioreactors used by the team. In addition, the selected bio-capacitance probes must allow multi-frequency scanning for real-time determination of the intrinsic dielectric properties of the cells through analysis of the ß-dispersion of the signal using the Cole–Cole a model. Finally, the generated data must be capable of being captured in real time both by the control and data acquisition system via OPC-UA communication, and via 4–20 mA communication to enable integration of the probe directly into a control loop.

Description

Acquisition of a new four-probe system enabling real-time measurement of bio-capacitance for cell culture in bioreactors, for up to four bioreactors in parallel. This system will enable real-time estimation of viable cell concentration in those bioreactors. Measuring bio-capacitance at multiple frequencies, at regular intervals, in order to obtain the capacitance distribution spectrum of the cells, thereby enabling the real-time calculation of other critical cell culture parameters such as cell ...

Dates

Publication
28 juillet 2026 à 20 h 00
Date de clôture
24 août 2026 à 10 h 00

Documents

Comment soumissionner

Classification

Catégories UNSPSC

41100000

Catégorie normalisée

Office Supplies & Equipment

Source: CanadaBuys

Dernière modification : 2026-09-09 21 h 01 min 09 s

Actualisation toutes les 2 heures