Langue de l’avis : Anglais · Aucun résumé vérifié en Français n’est disponible. Le texte enregistré est affiché; consultez les documents d’origine.

Tous les appels d’offres
AB-2026-02663 (BAR-2026-001-A)

BAR-2026-001 A Pembina Court Manor Wood Siding Upgrade

Barrhead and District Social Housing Association · Barrhead, Alberta, Canada

Cet appel d’offres a fermé le 24 avril 2026 à 10 h 00. Consulter les avis ouverts
Consulter la source

Temps restant pour soumissionner

Fermé

FerméConstruction et infrastructureProvincial

Renseignements généraux

Numéro de référence
AB-2026-02663 (BAR-2026-001-A)
Palier de gouvernement
Provincial
Type d’appel d’offres
Construction & Infrastructure
Titre
BAR-2026-001 A Pembina Court Manor Wood Siding Upgrade
Identifiant de la source
AB-2026-02663

Détails

Lieu
Barrhead, Alberta, Canada

Résumé

Description of Work/Specifications: Upgrade Wood Siding 1. Project Overview The BDSHA Representative is requesting proposals for the removal and disposal of existing exterior wooden siding, installation of new exterior insulation, and the supply and installation of new engineered wood composite siding at Pembina Court Manor. The intent of this project is to improve the building envelope’s durability, energy performance, and long-term maintenance characteristics. 2. Scope of Work Demolition and Removal Remove and dispose of existing wooden siding, trim, and associated components. Remove existing flashings associated with siding, trim, windows, doors, and other wall penetrations. Protect adjacent building elements, windows, doors, and landscaping during work. • Window guards on 2nd floor shall be salvaged for reinstallation by contractor upon completion of siding work. Substrate Preparation Inspect exposed wall assemblies following demolition. Complete minor repairs necessary for proper installation. Report any concealed damage or deficiencies to the BDSHA Representative prior to proceeding. Exterior Insulation Supply and install continuous exterior insulation board suitable for exterior wall applications. Insulation shall have a minimum thermal resistance of R-9. Install insulation to meet or exceed applicable building code requirements and minimize thermal bridging. Seal insulation joints and interfaces as required. Weather-Resistant Barrier Supply and install a continuous weather-resistant barrier (WRB) over insulation. Integrate WRB with existing building components, windows, doors, and penetrations. Flashings Supply and install new flashings at all locations affected by the work. Flashings shall be compatible with the WRB and siding system. All exposed flashings shall be painted or factory-finished to match the selected siding colour. Installation shall ensure proper drainage and weather-tightness. Trim, Mouldings, and Opening Adjustments Provide all necessary adjustments at windows, doors, and other wall penetrations to accommodate increased wall thickness. Supply and install appropriate trim, mouldings, or jamb extensions. This work is part of the base scope and not a change order. New Siding Installation Supply and install engineered wood composite siding manufactured by Maibec, V-Style (V-groove) profile, or approved equivalent. Siding shall be factory-finished, suitable for vertical installation. Colour to be selected by BDSHA upon award. Installation shall comply with manufacturer specifications and applicable codes. Minimum Siding Performance and Dimensional Requirements Engineered wood composite with high-density wood fiber core; nominal size approx. 12 ft length, 11-7/8 in. width, 3/8 in. thickness; factory-applied heat-cured finish; minimum 25-year product warranty. 3. Schedule Work shall be scheduled upon notification of contract award, subject to coordination with BDSHA. Work hours shall generally be between 8:00 AM and 8:00 PM. Buildings must remain weather-tight at all times. OH&S Safety Plan or Certificate of Recognition (COR) Insurance: - General Liability Insurance with limits of not less than $5,000,000 inclusive per occurrence, against bodily injury, personal injury, and property damage, and including following endorsements: owner's and Contractor's protective; blanket written contractual; non-owned auto; and broad form property damage. - Contractor shall maintain automobile liability insurance on all vehicles owned, operated or licensed in the name of the Contractor and used in carrying out the obligations under this Contract in an amount not less than $2,000,000. Valid WCB Commodity: Exterior finishing materials, Siding and exterior wall materials, Specialized trade construction and maintenance services, Roofing and siding and sheet metal services, Siding installation and repair service

Description

Description of Work/Specifications: Upgrade Wood Siding 1. Project Overview The BDSHA Representative is requesting proposals for the removal and disposal of existing exterior wooden siding, installation of new exterior insulation, and the supply and installation of new engineered wood composite siding at Pembina Court Manor. The intent of this project is to improve the building envelope’s durability, energy performance, and long-term maintenance characteristics. 2. Scope of Work Demolition and...

Dates

Publication
2 avril 2026 à 07 h 19
Date de clôture
24 avril 2026 à 10 h 00

Comment soumissionner

Classification

Catégories NIBS

3015000030151800721500007215260072152606

Catégorie normalisée

Construction & Infrastructure

Source: Alberta Purchasing

Dernière modification : 2026-09-09 21 h 01 min 53 s

Actualisation toutes les 2 heures